Vandalux Class2 Emergency Weathrproof Batten
The Australian designed Vandalux Class2 (double insulated) Emergency Weatherproof Batten range has a proven and trusted history since the early 1970 for being tough for all levels of heavy industrial and public applications including transport, heavy industry and high vandalism / secure areas where high surge immunity is required. The 6mm² terminal block, additional surge protection, replaceable fuse, class2 control gear tray (double insulated), emergency control gear with 4 hour Lithium Iron Phosphate battery & control gear has been selected to provide simplification, efficiency and versatility with Lumen Select Technology in the same traditional fitting allowing for easier and faster installation allowing for the same appearance throughout your installation. Replaceable retrofit kits and gear trays are available for when upgrades are required onsite.
- Chromated pressure die-cast LM6 marine grade aluminium body with RAL9007 powder coated paint finish and robust frosted polycarbonate lens resist impact & abuse (clear lens available)
- Mulitple wattages/Lumen outputs in 1 fitting, Two sizes available 4FT (22W, 30W, 37W, 53W, 63W) and 2FT (16W, 20W, 28W, 33W)
- Emergency control gear with 4 hour Lithium Iron Phosphate battery and Self Test (if not Connected to DALI)
- Large 6mm² terminal block, Samsung LEDs and European DALI2 driver, 10KV surge immunity, class2 control gear tray (double insulated) and replaceable fuse
- 20mm screwed cable entries on the end of the housing and muliple drill points in the back of the housing for cable entries. 25mm cable screwed cable entries available upon request.
- Replaceable gear tray and retrofit kits available as replacement for older LED and flourescent control gear
- Large range of mounting accessories available up on request.
- View Non Emergency Version
Product Specifications
Add To Ideas | Item Datasheet | IES | Item Code | Description | System Power | Exit Lumen | Lm/W | CCT | Inrush Current Duration | Line Current | Surge Protection | Electrical Rating | Earth Leakage | Dimensions | Luminaire Colour | Weight | Luminaire Material | Installation Type | Option | Testing System | Battery Voltage | Battery Capacity | Emergency Mode Wattage | Emergency Mode Lumen | Classification |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Add to ideas | VXOLS2D4M4CL2PB | VANDALUX OPAL 2FT LUMEN SELECT DALI 4K MAINTAINEDEMERGENCY 4HOUR CLASS 2 C/W RAIL SPEC | 28W | 3351lm | 121lm/W | 4000K | 46μs | 0.23A | Yes | Class II | 0.4mA | L700 x W138 x H114 mm | Grey RAL9007 | 4kg | Aluminium (Die Cast) | Surface Mounting | Maintained | Self-Test or DALI2 Monitoring | 6.4V | 3200mA | 5W | 745lm | C0/C180: D50 C90/C270: D25 | ||
Add to ideas | VXOLS4D4M4CL2PB | VANDALUX OPAL 4FT LUMEN SELECT DALI 4K MAINTAINED EMERGENCY 4HOUR CLASS 2 C/W RAIL SPEC | 53W | 6153lm | 114lm/W | 4000K | 46μs | 0.23A | Yes | Class II | 0.4mA | L1310 x W138 x H114 mm | Grey RAL9007 | 8kg | Aluminium (Die Cast) | Surface Mounting | Maintained | Self-Test or DALI2 Monitoring | 6.4V | 6000mA | 5W | 817lm | C0/C180: D100 C90/C270: D63 |